A Mastervolt battery monitoring panel brings an end to nasty surprises, like a sudden shortage of battery power.
The Masterlink BTM-III battery monitor provides an accurate indication of the current, amperage, remaining time and remaining capacity of battery bank 1, and the current and estimated capacity of battery banks 2 and 3. The built-in microprocessor calculates the remaining capacity and stores historic data.
The Masterlink BTM-III includes ten languages: English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish and Finnish.
General specifications | ||
Number of battery outlets | 3 (service, starter & bowthruster) | |
Display/read-out | voltage, current, Amp-hours, time remaining, battery capacity in %voltage, current, amp-hours, time remaining, battery capacity in %, special battery status events | |
Languages on display | English, Dutch, French, Spanish, German, Danish, Finnish, Norwegian, Italian, Swedish | |
Built-in depth |
40 mm, incl. cover and cable: 55 mm 1.6 inch |
|
Dimensions, hxwxd |
65 x 120 x 40 mm 2.6 x 4.7 x 1.6 inch |
|
Dimensions shunt, hxwxd |
84 x 44 x 44 mm 3.3 x 1.7 x 1.7 inch |
|
Weight |
0.25 kg 0.6 lb |
|
Technical specifications | ||
Max. Ah capacity | 9999 Ah | |
Supply voltage | 8-50 V | |
Voltage range | 7-35 V | |
Current consumption (backlight off) | 28 mA/12 V, 16 mA/24 V | |
Current consumption (backlight on) | 100 mA/12 V, 50 mA/24 V | |
Voltage resolution | 0.01 V | |
Voltage accuracy | ± 0.6 % | |
Shunt specification | 500 A/50 mV (service set) | |
Current measurement range | 0-500 A (optional 1000 A) | |
Current accurancy | ± 0,8 % | |
Battery alarm contact | yes, open collector | |
Remaining time indication | yes | |
Historical data | yes | |
MasterBus compatible | no | |
Connection cable (6-wire) necessary | no | |
Modular cable necessary | no | |
MasterAdjust Software to configure, monitor and log your Mastervolt system (MasterBus-USB interface...
Dimensions of the cover box for Masterlink remote panels (zipped DXF and PDF-file)
Guide for Quick installation and Basic operation of the Masterlink BTM-III (English)